titleUnique Metadata

Unique Metadata

Allows you to add unique metadata to the workspace dialog created here. This The Unique Metadata section requires the addition of the Unique ID metadata, which distinctly identifies each new workspace requested in the external system. This metadata is displayed in the selected panel.

  1. Click the Add New button in the far right column to assign unique metadata to the workspace.

  2. Configure the metadata In the Add Unique Metadata window.

Field

Description

Metadata

Select the metadata from the drop-down. To assign a metadata, either click the drop-down menu and select from the list or manually enter the value, which will auto-complete if it is assigned in Administration>Metadata.

Default Value

Select the default value to be assigned to the metadata. Manually enter a value for the field or the drop-down will display values if it is assigned in Administration>Metadata>Manage.

Display Label

Enter a display name for the metadata. Make this as specific as needed to differentiate between similar metadata names that may exist.

Note

Warning: The display name should not be composite.

Help Text

Enter help text to be displayed as a tool-tip on the custom field.

Type

Select the type of metadata from the drop-down. Options include:

  • Date: Represents date value (e.g. 2018-10-10)

  • String: Alphanumeric characters (e.g. cam123)

  • Boolean: Represent logical values (e.g. True or False)

  • Number: Numeric data values (e.g. 1,2,3)

  • Currency: Represents integer format (e.g. 123.456)

Look Up

Select Yes to include the Metadata as a look up field.

Note: This option is disabled for selection, if the Lookup option is set as No when adding the Metadata in CAM.

Lookup Type

  • Internal - The values in the drop-down are populated from the CAM metadata. You can select the metadata values from the drop-down.

  • External - The values in the drop-down are populated from the configured external system. You can select the metadata values from the drop-down.

Create a new value?

Select value. Select Yes to add a new value to the look up field.

A sign is added next to the lookup field in the panel.

Lookup new Option

Select one of the following options:

  • Generate New Number. CAM automatically generates a numeric value based on the Max digit and Metadata range specified in the dialog.

  • Use description as alias. CAM will auto add the metadata name as the alias metadata ID. The Create a new value must be set to Yes.

  • Generate read only new number. Allows a read only field in the Workflow.

  • Generate new number and hide. (For hidden system fields like systemid)

Note: AutoGeneration is automatically done for the systemid column so that the references remain unique. Prefixes are also supported on top of the auto generated number.

Total digit for metadata

Only displayed if Generate New Number option selected

Enter the length of the metadata to be generated for the custom entry (e.g. 5)

Prefix

Enter the metadata prefix

Metadata Range From & To

Only displayed if Generate New Number option selected

Enter the lowest & highest value of the metadata range that can be accessed

Is ID field hidden

Only displayed if Use description as alias option selected

Select Yes to hide the field in the Create Workspace Wizard.

Order

Set the order of the metadata to be displayed on the panel.

Panel

Select the panel for the metadata to be displayed. Based on the selection here the fields will be displayed in the panel.

Editable

Select Yes to allow the metadata value to be edited in the workspace dialog.

Lock Existing Values

This option doesn't allow users to create a new workspace using previously added values of specific metadata, locking the existing metadata.

When a new Unique Metadata field in Configure Wizard is added, the option to Lock Existing Values displays. If Lock Existing Values is selected as YesCreate a new value option should be automatically selected as Yes. The option No should be disabled. Also, the Default Value option is disabled.

If the Metadata with Lock Existing Values option is 'No', then users can only add values to Metadata by clicking the '+' button. After the user enters values for that Metadata, there is a validation to check if that value already exists. If the value already exists, the user should not be able to save that value.

E.g. Lock existing set to yes and is parent set to yes, means the unique metadata field matter will not allow inputting duplicate matters if any parent matters exist. If no for parent, and yes for lock, then if the metadata exists in entire system, then the value can't be added.

  1. Click Save to add unique metadata or click Cancel to close the dialog.

Note: The panels that have metadata specified here, will be displayed in the request workflow to enter information for the dialog.

For 'Grant Access' and 'Create Channel', Unique Metadata is not mandatory.

...